The Button Functions on the 7500E can be configured to allow employees to press IN or OUT before inserting the card. This is primarily done when the employee works longer than the Max In Value or to prevent an E-52 error on the display. To set the button functions:
- Remove the top cover.
- Press and hold the FUNCTION button for 3 seconds.
- When the unit beeps, release the FUNCTION
- Press the FUNCTION button and move the indicator mark next to Button Function.
- Press the CHANGE button to choose a setting.
Required |
IN or OUT MUST be pressed before inserting a card. |
Optional |
IN or OUT is only pressed to override the Max In Value. |
Disabled |
IN and OUT buttons cannot be used. |
- Press SET to save the change.
- Press SET again to exit the Programming Mode.
When completed, the 7500E should return to the normal display.