The dip switches for the DWA-S control Daylight Saving Time, operations, time display and time keeping. By default, when the DWA-S is shipped from the manufacturer, the dip switches are all set in the ON position.
Dip Switches 1, 2, and 3 are monitored at all times. Any changes made to these three dip switches take effect immediately. Dip Switch 4 is read only at power up to determine if the unit is a signalling Device or an ON/OFF Controller. The dip switches are on the inside left panel. |
||||
DS |
Description |
ON |
OFF |
|
1 |
Time Keeping Frequency |
60 Hz |
50 Hz |
|
2 |
Time Format |
12 Hr |
24 Hr |
|
3 |
Daylight Savings Time |
Enabled |
Disabled |
|
4 |
Operation |
Bell Ringer |
On/Off Controller |
In order to switch the operations from signalling device to on/off controller, the DWA-S MUST be powered down and back up. The unit only recognizes changes to dip switch #4 on power up of the unit.
After the DWA-S dip switches are configured, the DWA-S should be operable again. For further assistance, contact our Technical Support Department at 404-691-1064.