The DWA-S must be programmed with the date, the time, security code and events for bell ringing or as a controller. When the timer is shipped from the manufacturer, it is shipped as a signalling device. These events should occur for the specified signal length. To program scheduled events:
- If a security code was set, enter the Security Code. The display should read SELECT FUNCTION.
- Press RUN.
- Press PGRM EVENTS. The display should show SIGNAL: 12:00AM. If it shows CONTROL: 12:00AM, the operation of the unit must be changed.
- Press FAST FWD or SLOW FWD to set the time of the event.
- Select the Days of the Week.
- Select the next time.
- Select the Days of the Week.
- Repeat the process of setting the time and days of the week for all events.
- Press RUN when all events are programmed.
- Press PGRM REVIEW to review the events programmed.
- Erase any events as needed.
The DWA-S Sonachron Program Timer should return to the normal display. The day of the week will be determined automatically based on the date. For further assistance, contact our Technical Support Department at 404-691-1064.