DWA-S Sonachron is preset to change for Daylight Saving Time. The program timer must have the Dip Switch for Daylight Saving Time is set to the ON position. The DWA-S Sonachron Program Timer had an update due to changes to Daylight Saving Time in 2005.
To set the dip switch in the ON position, remove the Left Panel Cover from the bell ringer.
This will expose the battery, serial number label and the front circuit board's left end, where the dip switches are located. |
|
Review the Dip Switch Setting for Daylight Saving Time to make sure it is in the On Position, for locations that recognize Daylight Saving Time. |
||||
DS |
Description |
ON |
OFF |
|
1 |
Time Keeping Frequency |
60 Hz |
50 Hz |
|
2 |
Time Format |
12 Hr |
24 Hr |
|
3 |
Daylight Savings Time |
Enabled |
Disabled |
|
4 |
Operation |
Bell Ringer |
On/Off Controller |
After the DWA-S has the updated front panel and/or EPROM and the dip switch setting is set accordingly, the DWA-S should adjust automatically for Daylight Saving Time. For further asstance, contact our Technical Support Department at 404-691-1064.