The model PC600 will reach end-of-life on August 31, 2025, and will no longer be able to connect to PayClock Online software. Lathem is offering existing PayClock Online customers with a model PC600 a significant discount to upgrade to the current replacement model PCEXPRESS. The PCEXPRESS is a plug-in-play replacement for the PC600, with higher performance, available Wi-Fi or Ethernet connectivity, and uses the same employee badges as the PC600 for a seamless employee experience. Use the link below to order your replacement PCEXPRESS time clock(s) at this special discounted price, including fast free shipping. To learn more about upgrading your PC600 Time Clock click here. |
The Live Sync feature of the PC600 allows employee punches to be transferred instantly to the PayClock Database and employee information to be transferred from the database to the terminal periodically. If the PC600's display does not show the Live Sync arrows:
- On the PayClock Server, click the PayClock Orb in the software.
- Click Support Assistant.
- Make note of the IP Address.
- Click the Terminal Manger
- Click the PC600 in the Terminals list and review the Server IP.
- If the IP Address noted is different from the Server IP, click Get Server IP.
- Verify the IP Address is that of the PayClock Server.
- Click Save and Update the terminal.
- Review the PC600 to see if the Live Sync arrows are displayed.
- If they are not displayed, open Services.msc.
- Look for and highlight the PayClock Network Terminal Service.
- If it is not started, start the PayClock Network Terminal Service.
This should activate the Live Sync feature on the terminal. If the problem persists, contact our Technical Support Department at 404-691-1064.